Schneider Schneider TeSys LRD16 Thermal Overload Relay 9–13A For LC1D12–LC1D38 | LRD16
Schneider TeSys LRD16 Thermal Overload Relay 9–13A For LC1D12–LC1D38 | LRD16 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 9–13 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Network Type: AC / DC- Network Frequency: 0–400 Hz- Mounting Type: Direct Under Contactor / Rail or Plate with Accessories- Connection Type: Screw Terminals- Rated Insulation Voltage: 690 V IEC / 600 V UL-CSA- Rated Operational Voltage: 690 V AC- Rated Impulse Withstand Voltage: 6 kV- Tripping Threshold: 1.14 ± 0.06 × Ir- Model: LRD16- Product ID: LRD16- EAN: 3389110346824- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD16- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD14 Thermal Overload Relay 7–10A For LC1D09–LC1D38 | LRD14
Schneider TeSys LRD14 Thermal Overload Relay 7–10A For LC1D09–LC1D38 | LRD14 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 7–10 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Terminals- Rated Insulation Voltage: 690 V IEC- Rated Operational Voltage: Up to 690 V AC- Rated Impulse Withstand Voltage: 6 kV- Model: LRD14- Product ID: LRD14- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD14- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD12 Thermal Overload Relay 5.5–8A For LC1D09–LC1D38 | LRD12
Schneider TeSys LRD12 Thermal Overload Relay 5.5–8A For LC1D09–LC1D38 | LRD12 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 5.5–8 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Terminals- Rated Insulation Voltage: 690 V IEC- Rated Operational Voltage: Up to 690 V AC- Rated Impulse Withstand Voltage: 6 kV- Model: LRD12- Product ID: LRD12- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD12- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD10 Thermal Overload Relay 4–6A For LC1D09–LC1D38 | LRD10
Schneider TeSys LRD10 Thermal Overload Relay 4–6A For LC1D09–LC1D38 | LRD10 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 4–6 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: 690 V AC- Rated Impulse Withstand Voltage: 6 kV- Operating Frequency: 0–400 Hz- Dimensions: 45 × 66 × 70 mm- Weight: 0.124 kg- Model: LRD10- Product ID: LRD10- EAN: 3389110346794- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD10- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD32 Thermal Overload Relay 23–32A For LC1D25–LC1D38 | LRD32
Schneider TeSys LRD32 Thermal Overload Relay 23–32A For LC1D25–LC1D38 | LRD32 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 23–32 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Model: LRD32- Product ID: LRD32- EAN: 3389110346855- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD32- Unit: Pcs
$60.57
-
Schneider Schneider TeSys LRD08 Thermal Overload Relay 2.5–4A For LC1D09–LC1D38 | LRD08
Schneider TeSys LRD08 Thermal Overload Relay 2.5–4A For LC1D09–LC1D38 | LRD08 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 2.5–4 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Network Frequency: 0–400 Hz- Rated Impulse Withstand Voltage: 6 kV- Model: LRD08- Product ID: LRD08- EAN: 3389110346787- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD08- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD22 Thermal Overload Relay 16–24A For LC1D25–LC1D38 | LRD22
Schneider TeSys LRD22 Thermal Overload Relay 16–24A For LC1D25–LC1D38 | LRD22 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 16–24 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Model: LRD22- Product ID: LRD22- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD22- Unit: Pcs
$35.56
-
Schneider Schneider TeSys LRD21 Thermal Overload Relay 12–18A For LC1D18–LC1D38 | LRD21
Schneider TeSys LRD21 Thermal Overload Relay 12–18A For LC1D18–LC1D38 | LRD21 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 12–18 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Network Type: AC / DC- Network Frequency: 0–400 Hz- Rated Insulation Voltage: 690 V IEC- Rated Operational Voltage: 690 V AC- Rated Impulse Withstand Voltage: 6 kV- Tripping Threshold: 1.14 ± 0.06 × Ir- Model: LRD21- Product ID: LRD21- EAN: 3389110346831- Made in: Check Product Label / Country May Vary- Brand: Schneider Electric- Ref: SHNDR-LRD21- Unit: Pcs
$35.99
-
Schneider Schneider TeSys LRD07 Thermal Overload Relay 1.6–2.5A For LC1D09–LC1D38 | LRD07
Schneider TeSys LRD07 Thermal Overload Relay 1.6–2.5A For LC1D09–LC1D38 | LRD07 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 1.6–2.5 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Model: LRD07- Product ID: LRD07- EAN: 3389110346770- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD07- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD06 Thermal Overload Relay 1–1.6A For LC1D09–LC1D38 | LRD06
Schneider TeSys LRD06 Thermal Overload Relay 1–1.6A For LC1D09–LC1D38 | LRD06 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 1–1.6 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Network Type: AC / DC- Network Frequency: 0–400 Hz- Rated Insulation Voltage: 690 V IEC- Rated Operational Voltage: 690 V AC- Rated Impulse Withstand Voltage: 6 kV- Tripping Threshold: 1.14 ± 0.06 × Ir- Model: LRD06- Product ID: LRD06- EAN: 3389110346763- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD06- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD05 Thermal Overload Relay 0.63–1A For LC1D09–LC1D38 | LRD05
Schneider TeSys LRD05 Thermal Overload Relay 0.63–1A For LC1D09–LC1D38 | LRD05 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 0.63–1 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Model: LRD05- Product ID: LRD05- EAN: 3389110346756- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD05- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD04 Thermal Overload Relay 0.4–0.63A For LC1D09–LC1D38 | LRD04
Schneider TeSys LRD04 Thermal Overload Relay 0.4–0.63A For LC1D09–LC1D38 | LRD04 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 0.4–0.63 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Model: LRD04- Product ID: LRD04- EAN: 3389110346749- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD04- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD03 Thermal Overload Relay 0.25–0.40A For LC1D09–LC1D38 | LRD03
Schneider TeSys LRD03 Thermal Overload Relay 0.25–0.40A For LC1D09–LC1D38 | LRD03 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 0.25–0.40 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Rail or Plate with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Model: LRD03- Product ID: LRD03- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD03- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD02 Thermal Overload Relay 0.16–0.25A For LC1D09–LC1D38 | LRD02
Schneider TeSys LRD02 Thermal Overload Relay 0.16–0.25A For LC1D09–LC1D38 | LRD02 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 0.16–0.25 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Separate Mounting with Accessories- Connection Type: Screw Clamp Terminals- Rated Insulation Voltage: 690 V- Rated Operational Voltage: Up to 690 V AC- Weight: 0.124 kg- Model: LRD02- Product ID: LRD02- EAN: 3389110346725- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD02- Unit: Pcs
$30.84
-
Schneider Schneider TeSys LRD01 Thermal Overload Relay 0.1–0.16A For LC1D09–LC1D38 | LRD01
Schneider TeSys LRD01 Thermal Overload Relay 0.1–0.16A For LC1D09–LC1D38 | LRD01 - Product Type: Differential Thermal Overload Relay- Compatible With: Schneider TeSys LC1D09 / LC1D12 / LC1D18 / LC1D25 / LC1D32 / LC1D38 Contactors- Relay Technology: Thermal Bimetal, Differential- Relay Application: Motor Protection- Adjustable Current Range: 0.1–0.16 A- Trip Class: Class 10A- Phase Failure Protection: Yes- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount / Separate Mounting with Accessories- Connection Type: Screw Clamp Terminals- Network Type: AC / DC- Rated Insulation Voltage: 690 V IEC- Model: LRD01- Product ID: LRD01- EAN: 3389110346718- Made in: France- Brand: Schneider Electric- Ref: SHNDR-LRD01- Unit: Pcs
$30.84
-
MITSUBISHI Mitsubishi TH-N12KP 5A Thermal Overload Relay 4–6A For S-N10–S-N12 | TH-N12KP 5A
Mitsubishi TH-N12KP 5A Thermal Overload Relay 4–6A For S-N10–S-N12 | TH-N12KP 5A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N10 / S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal Bimetal- Adjustable Current Range: 4–6 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount- Optional Separate Mounting: With UN-HZ12 Adapter- Connection Type: M3.5 Screw Terminals- Rated Insulation Voltage: 690 VAC- Model: TH-N12KP 5A- Product ID: TH-N12KP 5A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-5A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N20KP 15A Thermal Overload Relay 12–18A For S-N20–S-N35 | TH-N20KP 15A
Mitsubishi TH-N20KP 15A Thermal Overload Relay 12–18A For S-N20–S-N35 | TH-N20KP 15A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N20 / S-N21 / S-N25 / S-N35 Contactors- Relay Technology: 3-Phase Thermal Bimetal- Adjustable Current Range: 12–18 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Separate Mounting- Connection Type: Screw Terminals- Main-Circuit Terminal Size: M4- Control-Circuit Terminal Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N20KP 15A- Product ID: TH-N20KP 15A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20KP-15A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N20KP 9A Thermal Overload Relay 7–11A For S-N20–S-N35 | TH-N20KP 9A
Mitsubishi TH-N20KP 9A Thermal Overload Relay 7–11A For S-N20–S-N35 | TH-N20KP 9A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N20 / S-N21 / S-N25 / S-N35 Contactors- Relay Technology: 3-Phase Thermal Bimetal- Adjustable Current Range: 7–11 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Separate Mounting- Connection Type: Screw Terminals- Main-Circuit Terminal Size: M4- Control-Circuit Terminal Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N20KP 9A- Product ID: TH-N20KP 9A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20KP-9A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N120KP 82A Thermal Overload Relay 65–100A For S-N125–S-N150 | TH-N120KP 82A
Mitsubishi TH-N120KP 82A Thermal Overload Relay 65–100A For S-N125–S-N150 | TH-N120KP 82A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N125 / S-N150 / SD-N125 / SD-N150 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 65–100 A- Heater Designation: 82 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Independent Mount or Contactor Mount with Connecting Parts- Connection Type: Screw Terminals- Rated Voltage: 690 V- Rated Motor Power: 22 kW at 220–240 VAC / 45 kW at 380–440 VAC- Operating Temperature: −10 to +40 °C- Dimensions: 103 × 67 × 105 mm- Weight: 0.48 kg- Model: TH-N120KP 82A- Product ID: 124428- Global Order Code: THA00-406- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N120KP-82A- Unit: Pcs
$30.00
-
MITSUBISHI Mitsubishi TH-N120KP 67A Thermal Overload Relay 54–80A For S-N125–S-N150 | TH-N120KP 67A
Mitsubishi TH-N120KP 67A Thermal Overload Relay 54–80A For S-N125–S-N150 | TH-N120KP 67A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N125 / S-N150 / SD-N125 / SD-N150 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 54–80 A- Heater Designation: 67 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Independent Mount or Contactor Mount with Connecting Parts- Connection Type: Screw Terminals- Rated Voltage: 690 V- Rated Motor Power: 18.5–19 kW at 220–240 VAC / 37 kW at 380–440 VAC- Operating Temperature: −10 to +40 °C- Dimensions: 103 × 67 × 105 mm- Weight: 0.48 kg- Model: TH-N120KP 67A- Product ID: 124427- Global Order Code: THA00-405- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N120KP-67A- Unit: Pcs
$44.60
-
MITSUBISHI Mitsubishi TH-N60TAKP 82A Thermal Overload Relay 65–93A For S-N95 | TH-N60TAKP 82A
Mitsubishi TH-N60TAKP 82A Thermal Overload Relay 65–93A For S-N95 | TH-N60TAKP 82A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N95 / SD-N95 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 65–93 A- Heater Designation: 82 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M6- Auxiliary Terminal Screw Size: M4- Rated Insulation Voltage: 690 V- Rated Motor Power: 22 kW at 220–240 VAC / 45 kW at 380–440 VAC- Model: TH-N60TAKP 82A- Product ID: 113716- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N60TAKP-82A- Unit: Pcs
$25.98
-
MITSUBISHI Mitsubishi TH-N20TAKP 35A Thermal Overload Relay 30–40A For S-N35 | TH-N20TAKP 35A
Mitsubishi TH-N20TAKP 35A Thermal Overload Relay 30–40A For S-N35 | TH-N20TAKP 35A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N35 / SD-N35 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 30–40 A- Heater Designation: 35 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M4 Power Side / M5 Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Rated Motor Power: 11 kW at 220–240 VAC / 18.5–19 kW at 380–440 VAC- Model: TH-N20TAKP 35A- Product ID: 59395- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20TAKP-35A- Unit: Pcs
$20.41
-
MITSUBISHI Mitsubishi TH-N20KP 19A Thermal Overload Relay 16–22A For S-N25–S-N35 | TH-N20KP 19A
Mitsubishi TH-N20KP 19A Thermal Overload Relay 16–22A For S-N25–S-N35 | TH-N20KP 19A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N25 / S-N35 / SD-N25 / SD-N35 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 16–22 A- Heater Designation: 19 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M4- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N20KP 19A- Product ID: TH-N20KP 19A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20KP-19A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N20KP 11A Thermal Overload Relay 9–13A For S-N20–S-N35 | TH-N20KP 11A
Mitsubishi TH-N20KP 11A Thermal Overload Relay 9–13A For S-N20–S-N35 | TH-N20KP 11A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N20 / S-N21 / S-N25 / S-N35 and SD-N20–SD-N35 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 9–13 A- Heater Designation: 11 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M4- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N20KP 11A- Product ID: TH-N20KP 11A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20KP-11A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N20KP 6.6A Thermal Overload Relay 5.2–8A For S-N20–S-N35 | TH-N20KP 6.6A
Mitsubishi TH-N20KP 6.6A Thermal Overload Relay 5.2–8A For S-N20–S-N35 | TH-N20KP 6.6A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N20 / S-N21 / S-N25 / S-N35 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 5.2–8 A- Heater Designation: 6.6 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M4- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N20KP 6.6A- Product ID: TH-N20KP 6.6A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20KP-6.6A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N20KP 5A Thermal Overload Relay 4–6A For S-N20–S-N35 | TH-N20KP 5A
Mitsubishi TH-N20KP 5A Thermal Overload Relay 4–6A For S-N20–S-N35 | TH-N20KP 5A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N20 / S-N21 / S-N25 / S-N35 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 4–6 A- Heater Designation: 5 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M4- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N20KP 5A- Product ID: TH-N20KP 5A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20KP-5A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N20KP 3.6A Thermal Overload Relay 2.8–4.4A For S-N20–S-N35 | TH-N20KP 3.6A
Mitsubishi TH-N20KP 3.6A Thermal Overload Relay 2.8–4.4A For S-N20–S-N35 | TH-N20KP 3.6A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N20 / S-N21 / S-N25 / S-N35 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 2.8–4.4 A- Heater Designation: 3.6 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M4- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N20KP 3.6A- Product ID: TH-N20KP 3.6A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N20KP-3.6A- Unit: Pcs
$18.56
-
MITSUBISHI Mitsubishi TH-N12KP 3.6A Thermal Overload Relay 2.8–4.4A For S-N11–S-N12 | TH-N12KP 3.6A
Mitsubishi TH-N12KP 3.6A Thermal Overload Relay 2.8–4.4A For S-N11–S-N12 | TH-N12KP 3.6A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 2.8–4.4 A- Heater Designation: 3.6 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M3.5- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 3.6A- Product ID: TH-N12KP 3.6A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-3.6A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-N12KP 2.5A Thermal Overload Relay 2–3A For S-N11–S-N12 | TH-N12KP 2.5A
Mitsubishi TH-N12KP 2.5A Thermal Overload Relay 2–3A For S-N11–S-N12 | TH-N12KP 2.5A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 2–3 A- Heater Designation: 2.5 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount with UN-HZ12- Connection Type: Screw Terminals- Main Circuit Terminal Screw Size: M3.5, Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 2.5A- Product ID: TH-N12KP 2.5A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-2.5A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-N12KP 2.1A Thermal Overload Relay 1.7–2.5A For S-N11–S-N12 | TH-N12KP 2.1A
Mitsubishi TH-N12KP 2.1A Thermal Overload Relay 1.7–2.5A For S-N11–S-N12 | TH-N12KP 2.1A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 1.7–2.5 A- Heater Designation: 2.1 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount with UN-HZ12- Connection Type: Screw Terminals- Main Circuit Terminal Screw Size: M3.5, Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 2.1A- Product ID: TH-N12KP 2.1A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-2.1A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-N12KP 1.7A Thermal Overload Relay 1.4–2A For S-N11–S-N12 | TH-N12KP 1.7A
Mitsubishi TH-N12KP 1.7A Thermal Overload Relay 1.4–2A For S-N11–S-N12 | TH-N12KP 1.7A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 1.4–2 A- Heater Designation: 1.7 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount with UN-HZ12- Connection Type: Screw Terminals- Main Circuit Terminal Screw Size: M3.5, Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 1.7A- Product ID: TH-N12KP 1.7A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-1.7A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-N12KP 1.3A Thermal Overload Relay 1–1.6A For S-N11–S-N12 | TH-N12KP 1.3A
Mitsubishi TH-N12KP 1.3A Thermal Overload Relay 1–1.6A For S-N11–S-N12 | TH-N12KP 1.3A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 1–1.6 A- Heater Designation: 1.3 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount with UN-HZ12- Connection Type: Screw Terminals- Main Circuit Terminal Screw Size: M3.5, Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 1.3A- Product ID: TH-N12KP 1.3A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-1.3A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-N12KP 0.9A Thermal Overload Relay 0.7–1.1A For S-N11–S-N12 | TH-N12KP 0.9A
Mitsubishi TH-N12KP 0.9A Thermal Overload Relay 0.7–1.1A For S-N11–S-N12 | TH-N12KP 0.9A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 0.7–1.1 A- Heater Designation: 0.9 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount with UN-HZ12- Connection Type: Screw Terminals- Main Circuit Terminal Screw Size: M3.5, Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 0.9A- Product ID: TH-N12KP 0.9A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-0.9A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-N12KP 0.7A Thermal Overload Relay 0.55–0.85A For S-N11–S-N12 | TH-N12KP 0.7A
Mitsubishi TH-N12KP 0.7A Thermal Overload Relay 0.55–0.85A For S-N11–S-N12 | TH-N12KP 0.7A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 0.55–0.85 A- Heater Designation: 0.7 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount with UN-HZ12- Connection Type: Screw Terminals- Main Circuit Terminal Screw Size: M3.5, Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 0.7A- Product ID: TH-N12KP 0.7A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-0.7A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-N12KP 0.5A Thermal Overload Relay 0.4–0.6A For S-N11–S-N12 | TH-N12KP 0.5A
Mitsubishi TH-N12KP 0.5A Thermal Overload Relay 0.4–0.6A For S-N11–S-N12 | TH-N12KP 0.5A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-N11 / S-N12 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 0.4–0.6 A- Heater Designation: 0.5 A- Trip Class: Class 10A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount or Independent Mount with UN-HZ12- Connection Type: Screw Terminals- Main Circuit Terminal Screw Size: M3.5, Load Side- Auxiliary Terminal Screw Size: M3.5- Rated Insulation Voltage: 690 V- Model: TH-N12KP 0.5A- Product ID: TH-N12KP 0.5A- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-N12KP-0.5A- Unit: Pcs
$15.35
-
MITSUBISHI Mitsubishi TH-T100KP 95A Thermal Overload Relay 85–105A For S-T100 | TH-T100KP 95A
Mitsubishi TH-T100KP 95A Thermal Overload Relay 85–105A For S-T100 | TH-T100KP 95A - Product Type: Thermal Overload Relay- Compatible With: Mitsubishi S-T100 / SD-T100 Contactors- Relay Technology: 3-Phase Thermal, 3-Element- Adjustable Current Range: 85–105 A- Heater Designation: 95 A- Number of Poles: 3P- Auxiliary Contacts: 1NO+1NC- Reset Mode: Manual or Automatic, Selectable- Mounting Type: Direct Contactor Mount- Connection Type: Screw Terminals- Main Terminal Screw Size: M6- Auxiliary Terminal Screw Size: M4- Rated Insulation Voltage: 690 V- Model: TH-T100KP 95A- Product ID: THA03-033- Made in: Japan- Brand: Mitsubishi Electric- Ref: MITSB-TH-T100KP-95A- Unit: Pcs
$30.29